Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 250
Filter
1.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533804

ABSTRACT

ABSTRACT Purpose: To compare the injection of small amounts of undiluted C3F8 with the traditional gas injection in vitrectomy for macular hole treatment. Methods: This clinical trial included 26 individuals divided into two groups. Group 1 received an intravitreal injection of 0.9-1.0 mL of 100% C3F8, and Group 2 received 15-20 mL of 20% C3F8. Results: The median intraocular gas duration was 31 days in Group 1 and 34 in Group 2. The median letter gains in corrected distance visual acuity for the 26th postoperative week were 20 letters in Group 1 and 12.5 in Group 2. The median intraocular pressure was normal in both groups. Primary anatomical success was 11/13 in both groups. Conclusions: The use of C3F8 gas in a small undiluted volume is an alternative that slightly reduces the duration of the gas without negatively affecting the anatomical and visual response.

2.
Arch. latinoam. nutr ; 73(supl. 2): 131-139, sept. 2023. tab
Article in Spanish | LILACS, LIVECS | ID: biblio-1537264

ABSTRACT

Introducción. La producción de alimentos es una de las principales causas de Emisiones de Gases de Efecto Invernadero (GEI). Estimar las emisiones GEI de la dieta es el punto de partida para definir dietas saludables y sostenibles con el ambiente. Objetivo. Estimar el total GEI de la dieta de mujeres adolescentes del oriente de Guatemala, así como la contribución de grupos de alimentos a este valor. Materiales y métodos. En el contexto de un estudio de agricultura y nutrición en el oriente de Guatemala, se realizó un análisis secundario de los datos dietéticos (Recordatorio de 24 horas) de 2082 mujeres adolescentes. Los alimentos reportados fueron enlazados con la base de datos SHARP, que contiene estimaciones de GEI para 944 alimentos. La variable de enlace fue un código único armonizado con el sistema de clasificación FoodEx2. Resultados. La dieta es poco diversa, principalmente a base de grupos de alimentos de origen vegetal, con poca presencia de alimentos de origen animal. El GEI de la dieta fue de 2,3 Kg CO2 eq/ per cápita/día, con la mayor contribución de comidas preparadas (26,7%) y panes, tortillas y similares (12,8%). Conclusiones. La dieta de las mujeres adolescentes de áreas rurales de Guatemala tiene un GEI inferior al reportado en otros países de la región para estratos socioeconómicos con mayor consumo de alimentos de origen animal. Este estudio es el punto de partida para sistematizar la metodología para continuar con las estimaciones de GEI en Guatemala(AU)


Introduction. Food production is one of the main causes of Greenhouse Gas Emissions (GHGE). Estimating GHG emissions from the diet is the starting point for defining healthy and environmentally sustainable diets. Objective. Estimate the total GHGE in the diet of adolescent women from eastern Guatemala, as well as the contribution of food groups to this value. Materials and methods. In the context of an agriculture and nutrition study in eastern Guatemala, a secondary analysis of dietary data (24-hour recall) of 2082 adolescent women was performed. The reported foods were linked to the SHARP database, which contains GHGE estimates for 944 foods. The linking variable was a unique code harmonized with the FoodEx2 classification system. Results. The diet is not diverse, mainly based on food groups of plant origin, with little presence of foods of animal origin. The GHG of the diet was 2.3 Kg CO2 eq/per capita/day, with the greatest contribution from prepared foods (26.7%) and breads, tortillas and similar products (12.8%). Conclusions. The diet of adolescent women in rural areas of Guatemala has a lower GHG than that reported in other countries in the region for socioeconomic strata with greater consumption of foods of animal origin. This study is the starting point to systematize the methodology to continue with GHG estimates in Guatemala(AU)


Subject(s)
Humans , Female , Child , Adolescent , Adult , Diet , Greenhouse Gases
3.
Acta bioeth ; 29(1): 17-25, jun. 2023.
Article in Spanish | LILACS | ID: biblio-1439071

ABSTRACT

Este artículo muestra que la experiencia acumulada por la Corte Suprema chilena en juicios sobre responsabilidad civil y ambiental, debiera permitirle abordar los problemas ético-ambientales y jurídicos que el calentamiento global implica, sea previniendo daños mediante la imposición a los principales emisores de gases de efecto invernadero, incluido el Estado, del deber de reducir acelerada y significativamente las emisiones, sea exigiendo y haciendo cumplir la obligación de adaptación al cambio climático mediante la atribución de responsabilidad extracontractual o ambiental.


This article shows that the experience accrued by the Chilean Supreme Court in lawsuits on tort and environmental liability, should allow it to address the ethical-environmental and legal issues that global warming implies, either by preventing harm through the imposition on the major emitters of greenhouse gases, including the State, of the duty to reduce emissions rapidly and significantly, or by demanding and enforcing the obligation to adapt to climate change through the attribution of tort liability or environmental liability.


Esse artigo mostra que a experiência acumulada pela Corte Suprema chilena em julgamentos sobre responsabilidade civil e ambiental, deveria permitir-lhe abordar os problemas ético-ambientais e jurídicos que o aquecimento global implica, seja prevenindo danos mediante a imposição aos principais emissores de gases de efeito estufa, incluindo o Estado, do dever de reduzir acelerada e significativamente as emissões, seja exigindo e fazendo cumprir a obrigação de adaptação à mudança climática mediante a atribuição de responsabilidade extracontratual ou ambiental.


Subject(s)
Humans , Chile
4.
Arch. latinoam. nutr ; 73(2): 90-101, jun. 2023. tab
Article in Spanish | LILACS, LIVECS | ID: biblio-1510006

ABSTRACT

El espacio de comedores son una forma de garantizar el acceso a alimentos seguros, saludables y medio ambientalmente responsables para los estudiantes universitarios. Objetivo. Este estudio tuvo como objetivo caracterizar los estándares del menú, a partir de la evaluación de la calidad nutricional y del impacto en el medio ambiente por los insumos utilizados para su elaboración por un Comedor Universitario (CU) en Uruguay. Materiales y métodos. Se trató de un estudio de caso retrospectivo, relativo al año 2021. Las variables evaluadas fueron a) cantidad total de alimento comprado en kilogramos (kg); b) cantidad en kilocalorías (kcal) e impactos ambientales por: c) generación de residuos; d) huella hídrica (HH); y e) gases de efecto invernadero (GEI). También se realizaron cálculos para evaluar la ecoeficiencia (EE). Resultados. El CU sirvió 33.740 comidas en 2021, de las cuales el 87,1% fueron almuerzos. De los 78 tipos de alimentos comprados, 41 de ellos representaron el 93,17% del total en kilogramos. En la calidad nutricional, menos del 10% se clasificaron como alimentos procesados o ultraprocesados. En la evaluación de aspectos nutricionales e impactos ambientales, los alimentos de origen animal representaron el 26,52% del total en kg y el 69,78% de los HH. Un alimento de origen vegetal tuvo el mayor impacto de GEI debido a su origen. En cuanto a la EE, la valoración general mostró un resultado de 0,0626 para los alimentos de origen animal y 0,3838 para los de origen vegetal. Conclusiones. Corresponde a los servicios de alimentación para colectividades considerar, en la planificación del menú, además de la calidad nutricional y sanitaria de la oferta alimentaria, los impactos ambientales que estas genera(AU)


The canteens are a way to guarantee access to safe, healthy and environmentally responsible food for university students. Objective. The purpose of this research was to characterize the menu standards, based on the evaluation of the nutritional quality and the environmental impact of the inputs used for its preparation by a university canteen in Uruguay. Materials and methods. This was a retrospective case study, relating to the year 2021. The variables evaluated were a) total amount of food purchased in kilograms (kg); b) quantity in kilocalories (kcal) and environmental impacts due to: c) waste generation; d) water footprint (WF); and e) greenhouse gases (GHG). Calculations were also performed to assess eco-efficiency (EE). Results. The university canteen served 33,740 meals in 2021, of which 87.1% were lunches. Of the 78 types of food purchased, 41 of them represented 93.17% of the total in kilograms. In nutritional quality, less than 10% are classified as processed or ultra-processed foods. In the evaluation of nutritional aspects and environmental impacts, foods of animal origin represented 26.52% of the total in kg and 69.78% of WF. A vegetal based food had the highest GHG impact due to its origin. Regarding the EE calculations, the general assessment showed a result of 0.626 for foods of animal origin and 0.3838 for those of vegetable origin. Conclusions. It corresponds to the food services for communities to consider, in the planning of the menu, in addition to the nutritional and sanitary quality of the food offer, the environmental impacts that it generates(AU)


Subject(s)
Humans , Male , Female , Universities , Food Quality , Environment , Food Hygiene , Food Handling , Food, Processed
5.
CienciaUAT ; 17(2): 24-36, ene.-jun. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1447821

ABSTRACT

RESUMEN Existe un interés global en la detección de gases tóxicos, para la protección del medio ambiente y los seres humanos. Se han desarrollado múltiples estudios enfocados en el uso de sensores de gases basados en óxidos metálicos, como es el óxido de zinc (ZnO), el cual presenta propiedades electrónicas específicas como sensor de gases por ser un semiconductor tipo n y bajo costo de producción. El objetivo de este trabajo fue analizar el uso de nanoestructuras de ZnO, para la fabricación de sensores del gas ácido sulfhídrico (H2S), así como las técnicas de obtención más comunes de dichas estructuras. Las características de las nanoestructuras de óxido de zinc (NE´s-ZnO) varían por efecto del método de obtención, generando diferentes morfologías y tamaño, que impactan en la capacidad de detección de gas (0.5 ppm a 600 ppm) y en el rango de temperatura que se requiere. Los avances en la generación de diversas NE´s-ZnO facilitarán la posibilidad de generar sensores que puedan ser utilizados en detectores portátiles y operen a temperatura ambiente, lo cual es un reto actual.


ABSTRACT There is a global interest in the detection of toxic gases for the protection of the environment and human beings, using low-cost and easy-to-use sensors. Multiple studies have focused on the use of gas detectors based on metal oxides, such as zinc oxide (ZnO), which has specific electronic properties as a gas detector because it is an n-type semiconductor and it has a low production cost. The objective of this work was to analyze the use of ZnO nanostructures for the manufacturing of hydrogen sulfide (H2S) gas sensors, as well as the most common techniques for obtaining these structures. The characteristics of zinc oxide nanostructures (NE´s-ZnO) vary due to the effect of the obtaining method, generating different morphologies and sizes, which impacts gas detection performance (0.5 ppm up to 600 ppm) and in the temperature range that is required. Advances in the design of various NE's-ZnO will have the possibility of generating sensors that can be used in portable detectors and operate at room temperature, which is a current challenge.

6.
Indian J Ophthalmol ; 2023 May; 71(5): 2234-2236
Article | IMSEAR | ID: sea-225056

ABSTRACT

A 62-year-old woman was referred with poor vision following manual small incision cataract surgery. On presentation, the uncorrected distance visual acuity in the involved eye was 3/60, whereas slit-lamp examination revealed a central corneal edema with the peripheral cornea relatively clear. Direct focal examination with a narrow slit upper border and lower margin of detached rolled up Descemet’s membrane (DM) could be visualized. We performed a novel surgical approach, “double-bubble pneumo-descemetopexy.” The surgical procedure included unrolling of DM with “small air bubble” and descemetopexy with “big bubble.” No postoperative complications were observed, and best corrected distance visual acuity improved to 6/9 at 6 weeks. The patient had a clear cornea and maintained BCVA 6/9 during 18 months at follow-up. Double-bubble pneumo-descemetopexy, a more controlled technique, provides a satisfactory anatomical and visual outcome in DMD without the need for endothelial keratoplasty (Descemet’s stripping endothelial keratoplasty or DMEK) or penetrating keratoplasty.

7.
Rev. invest. clín ; 75(1): 29-36, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1450100

ABSTRACT

ABSTRACT Background The values of arterial blood gases (ABG) change with altitude above sea level; empirical verification is essential because ventilatory acclimatization varies with ethnicity and a population's adaptation. Objective The aim of the study was to describe ABG in a healthy population residing at 2,240 meters above sea level, to identify the mean level of alveolar ventilation (PaCO2), and to know whether a progressive increase in PaCO2 occurs with age and the impact of increasing body mass index (BMI). Methods We conducted a cross-sectional study in a referral center for respiratory diseases in Mexico City. Associations among variables with correlation coefficient and regression models of PaO2, SaO2, and P(A-a)O2 as dependent variables as a function of age, BMI, minute ventilation, or breathing frequency were explored. Results Two hundred and seventeen healthy subjects were evaluated with a mean age of 40 ± 15 years, mean of the PaO2 was 71 ± 6 mmHg, SaO2 94% ± 1.6%, PaCO2 30.2 ± 3.4 mmHg, HCO3 20 ± 2 mmol/L, BE-2.9 ± 1.9 mmol/L, and the value of pH was 7.43 ± 0.02. In a linear regression, the main results were PaO2 = 77.5-0.16*age (p < 0.0001) and with aging P(A-a)O2 tended to increase 0.12 mmHg/year. PaCO2 in women increased with age by 0.075 mmHg/year (p = 0.0012, PaCO2 =26.3 + 0.075*age). SaO2 and PaO2 decreased significantly in women with higher BMI 0.14% and 0.52 mmHg per kg/m2, (p = 0.004 and 0.002 respectively). Conclusion Mean PaCO2 was 30.7 mmHg, implying a mean alveolar ventilation of around 30% above that at sea level.

8.
Med. crít. (Col. Mex. Med. Crít.) ; 37(1): 9-16, Feb. 2023. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1521183

ABSTRACT

Resumen: Introducción: el choque séptico es un subconjunto de sepsis en el que las anomalías circulatorias, celulares y metabólicas subyacentes son lo suficientemente profundas para aumentar de manera sustancial la mortalidad. Estos pacientes pueden ser identificados en un contexto clínico de choque séptico con hipotensión persistente. La importancia de vigilar valores de delta de pCO2 (presión parcial de dióxido de carbono) de 6 mmHg sirve como herramienta complementaria para evaluar el flujo sanguíneo adecuado hacia la demanda metabólica global. Objetivo: demostrar que el delta de pCO2 es útil en el manejo integral del paciente con choque séptico en la unidad de cuidados intensivos para dirigir el tratamiento de acuerdo con este biomarcador, que se registró al ingreso y a las 24 horas, se relacionaron al pronóstico y a la mortalidad en choque séptico. Material y métodos: estudio descriptivo, ambispectivo, longitudinal y analítico. El universo se compuso de los pacientes que ingresaron a la Unidad de Cuidados Intensivos del Hospital General «La Villa¼ y del Hospital General «Dr. Rubén Leñero¼. Diseño de la maniobra: se tomaron gasometrías arterial y venosa de los pacientes que ingresaron a la UCI, se calculó el delta de pCO2 para ver si los valores de este biomarcador estaban por arriba o debajo de 6 mmHg, ya que un delta de pCO2 se relaciona con mortalidad; sin embargo, el delta de pCO2 se comparó contra el lactato para correlacionar niveles mayores de lactato de 2 mmol/L con la mortalidad. y finalmente observar cuál de los dos biomarcadores es más útil. Se utilizó estadística descriptica para los resultados. Conclusión: de acuerdo a los resultados encontrados en este estudio, se puede decir que el delta de pCO2 y el lactato predijeron el fallecimiento de 15%, lo cual tiene una significancia positiva débil (p = 0.245).


Abstract: Introduction: septic shock is a subset of sepsis in which underlying circulatory, cellular, and metabolic abnormalities are profound enough to substantially increase mortality. These patients can be identified in a clinical setting of septic shock with persistent hypotension. The importance of monitoring delta pCO2 values of 6 mmHg serves as a complementary tool to assess adequate blood flow towards global metabolic demand. Objective: to demonstrate that the pCO2 delta is useful in the comprehensive management of patients with septic shock in the Intensive Care Unit to direct the treatment according to this biomarker (pCO2 delta) that was recorded at admission and at 24 hours, were related to prognosis and mortality in septic shock. Material and methods: descriptive, ambispective, longitudinal and analytical study. The universe was made up of patients admitted to the ICU of the La Villa and Rubén Leñero General Hospitals. Maneuver design: arterial and venous blood gases were taken from the patients admitted to the ICU, the pCO2 delta was calculated to see if the values of this biomarker were above or below 6 mmHg, since a pCO2 delta is related to with mortality; however, delta pCO2 was compared against Lactate to correlate lactate levels greater than two with mortality and finally see which of the two biomarkers is more useful. Descriptive statistics were used for the results. Conclusion: according to the results found in this study, it can be said that delta pCO2 and lactate predicted the death of 15%, which has a weak positive significance (p = 0.245).


Resumo: Introdução: choque séptico é um subconjunto de sepse em que anormalidades circulatórias, celulares e metabólicas subjacentes são profundas o suficiente para aumentar substancialmente a mortalidade, esses pacientes podem ser identificados em um cenário clínico de choque séptico com hipotensão persistente. A importância do monitoramento de valores Delta de pCO2 de 6 mmHg serve como ferramenta complementar para avaliar o fluxo sanguíneo adequado à demanda metabólica global. Objetivo: demonstrar que o Delta pCO2 é útil no manejo integral de pacientes com choque séptico na Unidade de Terapia Intensiva para direcionar o tratamento de acordo com este biomarcador (Delta pCO2) que foi registrado na admissão e em 24 horas, relacionado ao prognóstico e mortalidade no choque séptico. Material e métodos: estudo descritivo, ambispectivo, longitudinal e analítico. O universo foi constituído pelos pacientes internados na UTI dos Hospitais Gerais La Villa e Rubén Leñero. Desenho da estratégia: foram coletadas gasometrias arteriais e venosas dos pacientes internados na UTI, o Delta pCO2 foi calculado para ver se os valores desse biomarcador estavam acima ou abaixo de 6 mmHg, pois um Delta pCO2 está relacionado com mortalidade; entretanto, Delta pCO2 foi comparado com Lactato para correlacionar níveis de lactato maiores que 2 com mortalidade e finalmente observar qual dos dois biomarcadores é mais útil. Foram usadas estatísticas descritivas para os resultados. Conclusão: de acordo com os resultados encontrados neste estudo, pode-se dizer que Delta pCO2 e Lactato predizem óbito em 15%, o que tem uma fraca significância positiva (p = 0.245).

9.
Med. crít. (Col. Mex. Med. Crít.) ; 37(1): 26-30, Feb. 2023. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1521186

ABSTRACT

Resumen: Introducción: a través de los índices de oxigenación valoramos la función del sistema respiratorio de oxigenación y ventilación. Objetivo: determinar el valor de los índices de oxigenación como factor de pronóstico para el desenlace en neumonía grave por SARS-CoV-2. Material y métodos: estudio retrospectivo, longitudinal, descriptivo, analítico. Se incluyeron pacientes > 18 años con diagnóstico de neumonía por SARS-CoV-2 entre el 01 junio y el 31 de diciembre de 2020. Se clasificó a los pacientes de acuerdo al desenlace: sobreviviente o no sobreviviente. Se empleó estadística descriptiva y pruebas paramétricas y no paramétricas de acuerdo al caso, se construyeron curvas ROC (Receiver Operating Characteristic Curve) para determinar los puntos de corte de los gases arteriales con la mejor sensibilidad y especificidad y se determinó el área bajo la curva (ABC) para el desenlace fatal. Resultados: se incluyeron 175 pacientes, 70.3% correspondió al sexo masculino, la media de edad fue de 56 años (rango intercuartil 45-64). El grupo de sobrevivientes incluyó 51 pacientes y el grupo de no sobrevivientes 124 pacientes. Al analizar los gases arteriales al momento de ingresar a la unidad de cuidados intensivos sobresale la PaO2/FiO2 de 100 mmHg y el índice respiratorio (IR) > 2.4 con un ABC de 0.694 y 0.722 respectivamente. A las 96 horas de ingreso destaca PaO2/FiO2 de 145 mmHg, el IR >3 y la PaO2/PAO2 de 0.22 con un ABC de 0.846, 0.840 y 0.842 respectivamente. Conclusión: los gases arteriales medidos a las 96 horas de ingreso a la UCI son marcadores pronósticos para el desenlace fatal en la neumonía grave por SARS-CoV-2.


Abstract: Introduction: oxygenation indices we assess the function of the respiratory system of oxygenation and ventilation. Objective: to determine the value of arterial gases as a prognostic factor for the outcome of patients with severe SARS-CoV-2 pneumonia. Material and methods: retrospective, longitudinal, descriptive, analytical study. We included patients > 18 years with a diagnosis of SARS-CoV-2 pneumonia between 1 June and 31 December 2020. Patients were classified according to outcome: survivor or non-survivor. Descriptive statistics and parametric and non-parametric tests were used according to the case, ROC (Receiver Operating Characteristic Curve) curves were constructed to determine the cut-off points of arterial gases with the best sensitivity and specificity and the area under the curve (AUC) for the fatal outcome was determined. Results: we included 175 patients, 70.3% corresponded to the male sex, the mean age was 56 years (interquartile range 45-64). The survivor group included 51 patients and the non-survivor group 124 patients. When analyzing arterial gases at the time of admission to the ICU, paO2/FiO2 of 100 mmHg and respiratory index (RI) > 2.4 with ABC 0.694 and 0.722 respectively. At 96 hours of admission, PaO2/FiO2 of 145 mmHg stands out, the RI > 3 and the DA-aO2 of 0.22 with ABC 0.846, 0.840 and 0.842 respectively. Conclusion: arterial blood gases measured at 96 hours of ICU admission are prognostic markers for fatal outcome in severe SARS-CoV-2 pneumonia.


Resumo: Introdução: através dos índices de oxigenação avaliamos a função do sistema respiratório de oxigenação e ventilação. Objetivo: determinar o valor dos índices de oxigenação como fator prognóstico para o desfecho em pneumonia grave por SARS-CoV-2. Material e métodos: estudo retrospectivo, longitudinal, descritivo, analítico. Icluíram-se pacientes com mais de 18 anos de idade diagnosticados com pneumonia por SARS-CoV-2 entre 1º de junho e 31 de dezembro de 2020. Os pacientes foram classificados de acordo com o desfecho: sobreviventes ou não sobreviventes. Foram usadas estatística descritiva e testes paramétricos e não paramétricos de acordo com o caso, foram construídas curvas ROC (Receiver Operating Characteristic Curve) para determinar os pontos de corte da gasometria arterial com melhor sensibilidade e especificidade e determinou-se a área sob a curva (ABC) para o desfecho fatal. Resultados: incluíram-se 175 pacientes, 70.3% eram do sexo masculino, a média de idade foi de 56 anos (rango interquartil 45-64). O grupo sobrevivente incluiu 51 pacientes e o grupo não sobrevivente 124 pacientes. Na análise dos gases arteriais no momento da admissão na UTI, destacam-se a PaO2/FiO2 de 100 mmHg e o índice respiratório (IR) > 2.4 com AUC 0.694 e 0.722 respectivamente. Às 96 horas de internamento destaca-se PaO2/FiO2 145 mmHg, IR > 3 e PaO2/PAO2 de 0.22 com ABC 0.846, 0.840 e 0.842 respetivamente. Conclusão: os gases sanguíneos arteriais medidos 96 horas após a admissão na UTI são marcadores prognósticos para desfecho fatal em pneumonia grave por SARS-CoV-2.

10.
Arq. bras. oftalmol ; 86(5): e20230066, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513685

ABSTRACT

ABSTRACT Purpose: The study aimed to describe anatomic and visual outcomes associated with perfluoropropane intravitreal injection followed by laser treatment for macular retinal detachment secondary to optic disc pit. Methods: A single-center, retrospective study. Medical records of all patients treated at a tertiary retina referral center were evaluated between 2011 and 2018 for congenital optic disc pit-associated macular detachment with 0.3 ml 100% perfluoropropane intravitreal injection followed by retinal laser photocoagulation along the temporal optic disc margin as the initial treatment. Results: Six patients with optic disc pit-associated macular detachment were identified, with postoperative follow-up ranging from 13 to 52 months (mean: 28 months). Spectral domain optical coherence tomography (SD-OCT) showed complete fluid resolution without recurrence in five of the six cases. Four cases showed complete reabsorption after Intravitreal perfluoropropane plus laser, one patient needed an extra procedure (pars plana vitrectomy with inner limiting membrane peeling and pedicle flap inversion over the temporal optic disc margin) to achieve complete fluid reabsorption, and one patient had persistent intraretinal fluid and denied additional surgeries. The time between the initial procedure and total fluid reabsorption varied from 6.5 to 41 months (mean: 19.5 months). Best-corrected visual acuity improved after surgery on the last follow-up visit in all cases. Conclusion: 100% perfluoropropane intravitreal injection followed by photocoagulation along temporal optic disc margin was associated with anatomic and visual improvement in most cases, representing an alternative treatment approach for optic disc pit-associated macular detachment.


RESUMO Objetivo: Descrever os resultados anatômicos e visuais associados à injeção intravítrea de perfluoropropano seguida de tratamento a laser para descolamento de retina macular secundário à fosseta do disco óptico. Métodos: Estudo retrospectivo em um único centro. Foram revisados os prontuários médicos dos pacientes com descolamento macular associado a fosseta do disco óptico congênito em um centro de referência terciário de retina entre 2011 e 2018. Todos receberam como estratégia de tratamento inicial injeção intravítrea de perfluoropropano 100% seguido por fotocoagulação a laser ao longo da margem temporal do disco óptico. Resultados: Foram identificados seis pacientes com descolamento macular associado a fosseta do disco óptico durante o período do estudo. O seguimento pós-operatório variou de 13 a 52 meses, com média de 28 meses. SD-OCT demonstrou resolução completa do fluido em cindo dos seis casos, sem recorrência. Quatro casos apresentaram reabsorção completa após perfluoropropano intravítreo associado a laser, e um paciente necessitou de procedimento adicional (vitrectomia via pars plana com peeling da membrana limitante interna e inversão do retalho do pedículo sobre a margem temporal do disco óptico) para obter reabsorção completa de fluidos. Um paciente apresentou fluido intrarretiniano persistente e negou tratamentos adicionais. O tempo entre o procedimento inicial e a resolução completa do fluido variou entre 6,5 a 41 meses, com média de 19,5 meses. A acuidade visual corrigida melhorou após a cirurgia, considerando a última consulta de acompanhamento em todos os casos. Conclusão: A injeção intravítrea de perfluoropropano 100% seguida de fotocoagulação ao longo da margem temporal da margem do disco óptico foi associada à melhora anatômica e visual na maioria dos casos e representa uma abordagem terapêutica alternativa para o descolamento macular associado a fosseta do disco óptico.

11.
São José dos Campos; s.n; 2023. 88 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1525566

ABSTRACT

A mucosite oral é um quadro clínico que acomete frequentemente pacientes sob terapia antineoplásica na região de cabeça e pescoço e caracteriza-se por ulcerações na mucosa que geram intensa dor local, odinofagia, aumento do risco de infecções, do uso de antibióticos e do tempo de hospitalização. A correlação entre mucosite oral, infecção fúngica e o potencial de disseminação fúngica sistêmica foi recentemente descrita. Apesar do impacto desse quadro clínico sobre a qualidade e tempo de vida dos pacientes oncológicos, não há consenso sobre a profilaxia e o protocolo terapêutico. O plasma de baixa temperatura sobre pressão atmosférica (LTAPP) apresenta efeito antimicrobiano, anti-inflamatório e reparador tecidual, o que sugere que possa ser promissor no tratamento da mucosite oral. Os objetivos gerais deste projeto foram divididos em dois subprojetos: 1) Definir os melhores parâmetros in vitro com efeito antifúngico e não tóxico e avaliar o LTAPP no tratamento de lesão de mucosite oral em modelo murino de mucosite por quimioterapia e 2) avaliar se o tratamento com LTAPP pode prevenir a disseminação fúngica sistêmica em ratos a partir de infecção experimental de lesões de mucosite oral por Candida albicans. Para tal, foram incluídos no estudo 100 ratos (Rattus norvegicus) com 90 a 100 dias de idade. No subprojeto 1, a lesão de mucosite oral foi induzida por administração de 5 fluorouracila (5-FU), enquanto no subprojeto 2, utilizou-se 5-FU associada à cisplatina ambas associadas à aplicação tópica de ácido acético 50%. Para o subprojeto 1, os animais foram randomicamente divididos em 2 grupos experimentais (n=30): a) Grupo mucosite; b) Grupo mucosite tratado com LTAPP, avaliados após 1, 5 e 12 dias do tratamento. Durante o período experimental, as lesões foram fotografadas e a gravidade da mucosite classificada por meio da atribuição de escores. Após a eutanásia e o processamento, os cortes histológicos corados por hematoxilina-eosina (HE) foram analisados microscopicamente. Para o subprojeto 2, o estudo de disseminação sistêmica fúngica nos grupos de mucosite infectada com C. albicans tratado ou não com LTAPP foi conduzido pelo isolamento fúngico a partir de amostras de sangue total e macerado dos órgãos. Para tanto foram estudados 2 grupos de ratos (n=20): c) Grupo mucosite infectado com C. albicans e d) Grupo mucosite infectado com C. albicans tratada com LTAPP, avaliados após 24 e 72 h do tratamento. Para ambos os projetos, o melhor parâmetro in vitro foi selecionado, isto é aquele com maior atividade antifúngica e baixa toxicidade. Dessa forma, as lesões foram expostas ao LTAPP de hélio por 5 min na distância de 1,5 cm na potência de 1 W. Os resultados in vitro mostraram que o LTAPP teve efeito antifúngico e baixa toxicidade para células de mamíferos. Os resultados in vivo mostraram que 5-FU afetou a saúde geral dos animais, evidenciada pela perda de peso corporal. Em ambos os grupos, houve reparo tecidual após 12 dias do tratamento, com resolução quase completa da lesão, o que foi corroborado pelos achados microscópicos. O grupo LTAPP exibiu uma tendência maior de redução da lesão, após 12 dias de tratamento. Além disso, o LTAPP apresentou efeito inibitório sobre C. albicans após 5 minutos, de exposição, com redução da recuperação fúngica da língua após 24 h (p<0.05). A disseminação fúngica sistêmica foi reduzida significativamente após 24 e 72 h do tratamento. Com base nos resultados obtidos, conclui-se que o LTAPP é uma ferramenta promissora para futura aplicação clínica em pacientes com mucosite oral. (AU)


Oral mucositis is a clinical condition that frequently affects patients undergoing antineoplastic therapy in the head and neck region and is characterized by mucosal ulcerations that generate intense local pain, odynophagia, increased risks of infections, use of antibiotics and the length of hospital stay. The correlation among oral mucositis, fungal infection and the potential for systemic fungal dissemination has recently been described. Despite the impact of this clinical condition on the quality and life expectancy of cancer patients, there is no consensus on prophylaxis and the therapeutic protocols. Low temperature atmospheric pressure plasma (LTAPP) has antimicrobial, anti-inflammatory and tissue repairing effects, which suggests that it can be promising in the treatment of oral mucositis. The general objectives of this project were divided into two subprojects: 1) Define the best antifungal and non-toxic in vitro parameters and to evaluate the application of LTAPP in the treatment of oral mucositis in murine model for chemotherapy, and 2) to evaluate whether treatment with LTAPP can prevent systemic fungal dissemination in rats from experimental infection of oral mucositis lesions by Candida albicans. A total of 100 rats (Rattus norvegicus) aged 90 to 100 days were included in the study. In subproject 1, oral mucositis lesion was induced by administration of only 5- fluorouracil (5-FU), while in subproject 2, administration and systemic administration of 5-FU associated with cisplatin, both associated with topical application of 50% acetic acid. For subproject 1, the animals were randomly divided into 2 experimental groups (n=30):a) Mucositis group and b) Mucositis group treated with LTAPP evaluated after 1, 5 and 12 days of treatment. During the experimental period, the lesions were photographed, and the severity of mucositis was classified into scores. After euthanasia and processing, the histological cuts stained by hematoxylin-eosin (HE) were analyzed. For subproject 2, the study of fungal systemic dissemination in groups of mucositis infected with C. albicans treated or not with LTAPP was conducted by fungal isolation from whole blood and macerated organs. Therefore, 2 groups of rats (n=20) were studied: c) Mucositis group infected with C. albicans and d) Mucositis group infected with C. albicans treated with LTAPP, evaluated after 24 and 72 h of treatment. For both subprojects, the best in vitro parameter was selected, that is, the one with the greatest antifungal effect and low toxicity. Thus, the lesions were exposed to helium LTAPP for 5 min at a distance of 1.5 cm at power of 1 W. In vitro results showed that LTAPP has an antifungal effect and low toxicity. In vivo results showed that 5-FU affected the general health of animals evidenced by body weight loss. In both groups, there was tissue repair after 12 days of treatment, with almost complete resolution of the lesion, which was corroborated by the microscopic findings. LTAPP group showed a greater trend of reduction of lesion, after 12 days of the treatment. Furthermore, LTAPP showed inhibitory effect on C. albicans after 5 min of exposition, with reduction in fungal recovery from the tongue after 24 h (p<0.05). Reduction in fungal dissemination was observed after 24 and 72 h of LTAPP treatment (p<0.05). Based on the obtained results, it was concluded that LTAPP is a promising tool for future clinical application in patients with oral mucositis.(AU)


Subject(s)
Candida albicans , Mucositis , Plasma Gases
12.
Rev. cuba. pediatr ; 94(4)dic. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1441813

ABSTRACT

Introducción: El monóxido de carbono es uno de los mayores contaminantes de la atmósfera terrestre, su toxicidad es bien conocida por el ser humano. Las fuentes productoras responsables de aproximadamente 80 % de las emisiones de monóxido de carbono son los vehículos automotores que utilizan como combustible gasolina o diesel, los procesos industriales que utilizan compuestos del carbono y el fuego dentro de los hogares. Sus efectos tóxicos agudos incluida la muerte se han estudiados ampliamente, no así sus potenciales efectos adversos a largo plazo. Objetivo: Describir el comportamiento de la intoxicación aguda por monóxido de carbono en paciente pediátrico, su diagnóstico y tratamiento. Presentación del caso: paciente de 11 años de edad que sufre intoxicación aguda por monóxido de carbono. Ingresa en el Hospital Universitario procedente del primer nivel de atención médica como urgencia vital. Se estabiliza e identifican las alteraciones multisistémicas producidas por lesiones asociadas con la inhalación de humo y gases tóxicos en espacios cerrados. Se determina su correcto tratamiento. Conclusiones: La forma más pertinente de disminuir la morbilidad y la mortalidad en pacientes como el que se presenta, se basa en dos pilares: la correcta identificación y el acertado manejo para cada intoxicación. La aplicación de estos dos aspectos puede lograr un factor protector. Hay subregistro de la ocurrencia de los casos de intoxicación por monóxido de carbono que no son atendidos en los servicios de salud y de los que producen la muerte inmediata, por lo que es importante su diagnóstico y tratamiento oportuno.


Introduction: Carbon monoxide is one of the largest pollutants in the Earth's atmosphere, its toxicity is well known to humans. The producing sources responsible for approximately 80% of carbon monoxide emissions are motor vehicles that use gasoline or diesel as fuel, industrial processes that use carbon compounds and fire inside homes. Its acute toxic effects including death have been studied extensively, but its potential long-term adverse effects have not been studied. Objective: To describe the behavior of acute carbon monoxide poisoning in pediatric patients, their diagnosis and treatment. Case presentation: 11-year-old patient suffering from acute carbon monoxide poisoning. He is admitted to the University Hospital from the first level of medical care as a vital emergency. Multisystem alterations caused by lesions associated with the inhalation of smoke and toxic gases in enclosed spaces are stabilized and identified. Its correct treatment is determined. Conclusions: The most pertinent way to reduce morbidity and mortality in patients such as the one presented is based on two pillars: correct identification and correct management for each poisoning. The application of these two aspects can achieve a protective factor. There is underreporting of the occurrence of cases of carbon monoxide poisoning that are not treated in health services and those that cause immediate death, so their detection, diagnosis and timely treatment is important.

13.
rev. udca actual. divulg. cient ; 25(spe): e2160, jul. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1395212

ABSTRACT

RESUMEN Las actividades académicas, como los congresos, son muy importantes para la investigación y el desarrollo; sin embargo, las emisiones de carbono derivadas de la realización de eventos presenciales han mostrado estar muy por encima de las que producen eventos en línea. El objetivo de este trabajo fue estimar las emisiones generadas por el 5º Congreso Nacional y 1º Internacional de Ciencias Ambientales "Las Ciencias Ambientales en el Antropoceno", celebrado virtualmente, en su mayor parte. Se estimaron las emisiones del uso directo de computadores y de software (emisiones de los computadores, emisiones de la transferencia de los datos) y las emisiones de otras fuentes (reuniones de los organizadores, búsquedas y visitas a la página Web, uso de monitores externos y lámparas), así como las emisiones evitadas por transporte aéreo y terrestre. El congreso emitió 4,8 tCO2eq y evitó 33 tCO2eq. El desarrollo de eventos online o híbridos es más sostenible ambientalmente y podría ser más accesibles, a un mayor número de personas.


ABSTRACT Academic activities such as conferences are very important for research and development, however, carbon emissions derived from face-to-face events have been shown to be much higher than those produced by online events. The aim of this work was to estimate CO2 emissions generated by the 5th National Congress and 1st International Congress of Environmental Sciences "Environmental Sciences in the Anthropocene". Emissions from direct use of computers and software (emissions from computers, emissions from data transfer) and emissions from other sources (meetings of the organizers, searches and visits to the website, use of external monitors and lamps), as well as emissions avoided by air and land transport. The congress emitted 4.8 tCO2eq and avoided 33 tCO2eq. The development of online or hybrid events is more environmentally sustainable and could be more accessible to a greater number of people.

14.
Rev. bras. ter. intensiva ; 34(3): 351-359, jul.-set. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1407751

ABSTRACT

RESUMO Objetivo: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. Métodos: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. Resultados: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. Conclusão: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


ABSTRACT Objective: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. Methods: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. Results: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. Conclusion: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.

15.
Rev. Nac. (Itauguá) ; 14(1): 5-17, Junio 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1372723

ABSTRACT

RESUMEN Introducción: el portador de insuficiencia renal crónica puede presentar diversas alteraciones del estado ácido básico, siendo la acidosis metabólica la más frecuente. Objetivos: describir las características demográficas y clínicas y las alteraciones del estado ácido básico de pacientes adultos que ingresan con insuficiencia renal crónica en dos centros hospitalarios del Paraguay. Metodología: se aplicó un diseño observacional, descriptivo, transversal. Se incluyó a sujetos adultos de ambos sexos, portadores de insuficiencia renal crónica, que acudieron al Hospital Nacional (Itauguá) y Hospital Militar (Asunción) entre abril y noviembre del 2021. Se midieron variables antropométricas, clínicas y laboratoriales al ingreso. Los datos se sometieron a estadística descriptiva con el programa Epi Info 7™. El estudio contó con la aprobación del Comité de Ética de la Universidad Privada del Este, Paraguay. Resultados: se incluyó a 148 sujetos, siendo 78 (52,7 %) varones con edad media 58 ± 16 años y 70 (47,3 %) mujeres con edad media 54 ± 17 años. Las etiologías más frecuentes de la insuficiencia renal crónica fueron la diabetes mellitus e hipertensión arterial (44,5 %). Se detectó 12 sujetos (8,1 %) con gasometría normal. La alteración del estado ácido básico más frecuente fue la acidosis metabólica (87,2 %), predominando en este grupo los casos con brecha aniónica normal. Conclusiones: las alteraciones del estado ácido básico predominantes en pacientes con insuficiencia renal crónica fue la acidosis metabólica con brecha aniónica normal. Se sugiere aplicar los cálculos de los mecanismos compensadores para llegar al diagnóstico certero de estas alteraciones metabólicas.


ABSTRACT Introduction: the carrier of chronic renal failure can present various alterations of the basic acid state, being the metabolic acidosis the most frequent. Objectives: to describe the demographic and clinical characteristics and alterations in the acid-base status of adult patients admitted with chronic renal failure in two hospitals in Paraguay. Methodology: an observational, descriptive, cross-sectional design was applied. Adult subjects of both sexes, carriers of chronic renal failure, who attended the National Hospital (Itauguá) and the Military Hospital (Asunción) between April and November 2021 were included. Anthropometric, clinical and laboratory variables were measured at admission. The data was submitted to descriptive statistics with the Epi Info 7™ program. The study was approved by the Ethics Committee of the Universidad Privada del Este, Paraguay. Results: 148 subjects were included, being 78 (52.7 %) men with a mean age of 58 ± 16 years and 70 (47.3 %) women with a mean age of 54 ± 17 years. The most frequent etiologies of chronic renal failure were diabetes mellitus and arterial hypertension (44.5 %). 12 subjects (8.1 %) with normal blood gases were detected. The most frequent alteration of the acid-base status was metabolic acidosis (87.2 %), with cases with normal anion gap predominating in this group. Conclusions: the predominant acid-base status alterations in patients with chronic renal failure was metabolic acidosis with normal anion gap. It is suggested to apply the calculations of the compensatory mechanisms to arrive at the accurate diagnosis of these metabolic alterations.

16.
Ginecol. obstet. Méx ; 90(8): 639-646, ene. 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1404955

ABSTRACT

Resumen OBJETIVO: Determinar e interpretar los valores de la gasometría arterial en pacientes embarazadas con preeclampsia severa. MATERIALES Y MÉTODOS: Estudio observacional, transversal, retrospectivo y descriptivo llevado a cabo en pacientes con más o menos 20 semanas de embarazo y diagnóstico establecido de preeclampsia severa atendidas en la unidad de cuidados intensivos entre el 1 de julio y el 31 de diciembre del 2019. Los datos generales, la condición obstétrica, los estudios de laboratorio clínico y los valores de la gasometría arterial se documentaron conforme a lo registrado en los expedientes clínicos. Se utilizó estadística descriptiva y los datos se procesaron en el programa SPSS versión 20. RESULTADOS: Se estudiaron 30 pacientes con media de edad de 31.6 ± 6.85 años, mediana de paridad 1, todas con feto único de 33.89 ± 3.43 semanas y residencia en la Ciudad de México. Los valores de la gasometría arterial fueron: pH 7.41 ± 0.08, presión parcial de dióxido de carbono 25.51 ± 6.12 mmHg, presión parcial de oxígeno 85.24 ± 41.81 mmHg, hematocrito 33.86 ± 7.51%, ión carbonato 16.95 ± 5.13 mmol/L, patrón de bicarbonato estandarizado 19.04 ± 2.50 mmol/L, gases de efecto invernadero 16.94 ± 2.51 mmHg, exceso de base del fluido extracelular -7.72 ± 5.60 mmol/L, BE (B) -7.36 ± 3.07 mmol/L, porcentaje de saturación de oxígeno 93 ± 8.29, hemoglobina total en la gasometría arterial 10.64 ± 2.36 g/dL, gradiente alvéolo-arterial de oxígeno 49.43 ± 10.98 mmHg, presión parcial de oxígeno 140.43 ± 106.93 mmHg, concentraciones de dióxido de carbono 0.79 ± 0.28 mmHg e Índice respiratorio 0.95 ± 2.57. CONCLUSIONES: Los resultados corresponden a un patrón gasométrico de acidosis metabólica compensada.


Abstract OBJECTIVE: To determine and interpret arterial blood gas values in pregnant patients with severe preeclampsia. MATERIALS AND METHODS: study carry out in a series of 30 patients with a pregnancy ≥ 20 weeks and an established diagnosis of SP admitted to the Intensive Care Unit from July 1 to December 31, 2019, in whom arterial blood gases are part of the routine studies upon admission to the ICU. Patients with recurrence of preeclampsia, eclampsia and HELLP syndrome or with metabolic, respiratory, cardiological and renal morbidities affecting arterial blood gas values were excluded. The general data, obstetric condition, clinical laboratory and arterial blood gas values were documented from the clinical records. Statistical analysis: descriptive statistics were used with the statistical package SPSS version 20. RESULTS: Thirty patients were studied, with a mean age of mean age 31.6 ± 6.85 years, median parity 1, all with a single product of 33.89±3.43 weeks and residence in Mexico City 31.37 ± 7 years. Arterial blood gas values were: pH 7.41 ± 0.08, PCO2 25.51 ± 6.12 mmHg, PO2 85.24 ± 41.81 mmHg, Hct 33.86 ± 7.51%, HCO3- 16.95 ± 5.13 mmol/L, HCO3- std 19.04 ± 2.50 mmol/L, TCO2 16.94 ± 2.51 mmHg, BE ecf -7.72 ± 5.60 mmol/L, BE (B) -7.36 ± 3.07 mmol/L, SO2c% 93 ± 8.29%, THbc 10.64 ± 2.36 g/dL, Aa DO2 49.43 ± 10.98 mmHg, pAO2 140.43 ± 106.93 mmHg, PaO2/PAO2 0.79 ± 0.28 mmHg and Respiratory Index 0.95 ± 2.57. CONCLUSIONS: The results correspond to a gasometric pattern of compensated metabolic acidosis.

17.
Neumol. pediátr. (En línea) ; 17(4): 113-116, 2022. ilus
Article in Spanish | LILACS | ID: biblio-1427361

ABSTRACT

Las alteraciones de la relación entre la ventilación y el flujo sanguíneo (V/Q) en diversas regiones del pulmón alteran el aporte de oxígeno (O2) y remoción del dióxido de carbono (CO2) al organismo. Fisiológicamente existen diferencias regionales en la relación V/Q. Determinadas patologías pueden alterar esta relación, produciendo tres escenarios distintos: Cortocircuito (Shunt), Alteración V/Q y aumento del espacio muerto. Para evaluar estos escenarios y realizar una aproximación diagnostica son de utilidad el estudio de los gases arteriales y venosos, la diferencia alveolo arterial y la respuesta al suministrar O2


Alterations in the ventilation perfusion relationship (V/Q) in various lung regions alter the supply of oxygen (O2) and the removal of carbon dioxide (CO2) in the body. Physiologically, there are regional differences in the V/Q ratio. Certain pathologies can alter this relationship, producing three different scenarios: Shunt, V/Q mismach and dead space increased. To evaluate these scenarios and carry out a diagnostic approach, it is useful to study arterial and venous gasometry, the alveolar arterial difference and the response to oxygen supplying.


Subject(s)
Humans , Respiratory Physiological Phenomena , Ventilation-Perfusion Ratio/physiology , Blood Gas Analysis
18.
São Paulo; s.n; s.n; 2022. 111 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1396973

ABSTRACT

O objetivo desse trabalho foi identificar as consequências moleculares e funcionais da falta da proteína Ric8b no epitélio olfatório de camundongos. Para esse fim, comparamos o transcriptoma de epitélio olfatório de camundongos knock-out tecido específico para a proteína RIC8B (Ric8b cKO) com o dos seus irmãos tipo selvagem (WT). Identificamos muitos genes que apresentaram expressão reduzida no epitélio olfatório do camundongo Ric8b cKO, mas também vários genes que apresentaram a sua expressão aumentada. A maioria dos genes com expressão reduzida corresponde a genes normalmente expressos em neurônios olfatórios maduros, como por exemplo os genes de receptores olfatórios, o que é compatível com o fato já conhecido de que os camundongos Ric8b cKO apresentam um menor número desses neurônios. Inesperadamente, apesar de a maioria dos genes de receptores olfatórios ter a sua expressão diminuída no camundongo Ric8b cKO, observamos que um grupo destes genes de receptores teve a sua expressão aumentada. Os camundongos Ric8b cKO apresentaram também genes marcadores de outros tipos celulares que não neurônios canônicos com expressão aumentada no seu epitélio olfatório. Dentre eles, os mais significativamente alterados foram os genes marcadores de neurônios Trpc2+ tipo B (que expressam a guanilato ciclase solúvel Gucy1b2). Sabe-se que este tipo de neurônio é responsável pela sensibilidade a diferentes gases, e concordantemente, observamos que os camundongos Ric8b cKO apresentaram um aumento da sensibilidade a gás carbônico. Como o olfato apresenta um papel importante na regulação de ingestão alimentar, analisamos como os camundongos Ric8b cKO se comportam frente a diferentes dietas. Interessantemente, observamos que esses animais não apresentam preferência por alimento rico em gorduras quando comparado aos seus irmãos tipo selvagem. Nossos resultados sugerem, portanto, que a ausência da proteína RIC8B resulta na alteração de representatividade de neurônios canônicos e não canônicos no epitélio olfatório de camundongos, o que por sua vez leva a alterações funcionais e comportamentais


The objective of this work was to identify the molecular and functional consequences of the lack of the RIC8B protein in the main olfactory epithelium of mice. To this end, we compared the olfactory epithelium transcriptome of Ric8b tissue-specific knock-out mice (Ric8b cKO) with that of their wild-type littermates (WT). We identified many genes with differential expression, many of which were downregulated and also some which were upregulated in the olfactory epithelium of the Ric8b cKO mice. Most of the downregulated genes correspond to genes normally expressed in mature olfactory sensory neurons, such as olfactory receptor genes. This is compatible with the already known fact that the Ric8b cKO mice have less of this kind of neuron. Unexpectedly, even though most of the olfactory receptor genes were downregulated, we observed a subset of these genes that had their expression upregulated in the Ric8b cKO mice. The Ric8b cKO mice also showed upregulation for genes that are markers for cell types other than canonic neurons in their olfactory epithelium. Among these, the most significantly altered were the markers for neurons Trpc2+ type B (that express the soluble guanylate cyclase Gucy1b2). It is known that this kind of neuron is responsible for sensitivity to different gases. Accordingly, we observed that the Ric8b cKO mice presented a higher sensitivity to carbon dioxide. Since olfaction has an important role in food intake, we analyzed how the Ric8b cKO mice behaved with different diets. Interestingly, we observed that the Ric8b cKO mice lack preference for high fat diet when compared to their wild-type littermates. Our results indicate, therefore, that the lack of the RIC8B protein results in altered representativity of canonic and non-canonic neurons in the olfactory epithelium of mice, which then leads to altered function and behavior


Subject(s)
Animals , Male , Female , Mice , Olfactory Mucosa/abnormalities , Receptors, Odorant/agonists , Olfactory Receptor Neurons , Mice, Knockout , Feeding Behavior/classification , Neurons/chemistry , Absenteeism
19.
Braz. arch. biol. technol ; 65: e22210594, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1364464

ABSTRACT

Abstract: Brazil is a signatory to the Paris Agreement and aims to reduce 43% of CO2 emissions by 2030, compared to 2005. However, changes in energy policies are needed to achieve this goal, evaluating the produced effects on emissions. One way to predict these effects is through mathematical modeling. In this paper, we carried out a literature review to identify the most used model types and independent variables to forecasting Brazilian CO2 emissions. The review showed that gray models and artificial neural networks are the most used ones. Furthermore, we also identified that economic growth and energy consumption are the main independent variables.

20.
Med. crít. (Col. Mex. Med. Crít.) ; 36(8): 507-513, Aug. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506681

ABSTRACT

Resumen: Introducción: la asociación del nivel de lactato con la mortalidad en pacientes con sospecha de infección y sepsis está bien establecida. La sensibilidad es entre 66 y 83%, con especificidad de 80 y 85%. Sin embargo, el lactato no es sensible ni lo suficientemente específico para detectar o descartar el diagnóstico por sí solo, ya que el lactato sérico es un biomarcador importante de la hipoxia y disfunción tisular, pero no es una medida directa de la perfusión tisular. El lactato y la base estándar medidos al ingreso a la Unidad de Cuidados Intensivos (UCI) son de utilidad pronóstica en los pacientes críticamente enfermos, pues sus niveles séricos predicen mortalidad a través de la puntuación en sí misma. Pero la importancia real va más allá de un valor absoluto, pues es mejor medir su aclaramiento a través de un tiempo determinado. Objetivo: demostrar que el aclaramiento de lactato y déficit de base estándar registrados al ingreso y a las 24 h se relacionan con mejor pronóstico y disminución de mortalidad en choque séptico. Material y métodos: se utilizó estadística descriptiva (medidas de tendencia central y dispersión; así como frecuencias y porcentajes). Asimismo, se ocupó estadística inferencial con la prueba t de Student, χ2, curva ROC, área bajo la curva e índice de Youden, con un intervalo de confianza de 95%. Resultados: la asociación estadística con la mortalidad se presentó en el aclaramiento de déficit de base estándar y en aclaramiento de lactato. Conclusión: se demostró que el aclaramiento de lactato y déficit de base estándar registrados al ingreso y a las 24 h se relacionaron con mejor pronóstico y disminución de mortalidad en pacientes con choque séptico.


Abstract: Introduction: the association of lactate level with mortality in patients with suspected infection and sepsis is well established. Sensitivity is between 66 and 83%, with specificity between 80 and 85%. However, lactate is neither sensitive nor specific enough to detect or rule out the diagnosis on its own as serum lactate is an important biomarker of tissue hypoxia and dysfunction but is not a direct measure of tissue perfusion. Lactate and standard base measured on admission to the Intensive Care Unit (ICU) are useful for prognosis in critically ill patients since their serum levels predict mortality through the score itself. But the real importance goes beyond an absolute value, since it is better to measure its clearance over a given time. Objective: to demonstrate that lactate clearance and standard base deficit recorded at admission and at 24 hours are related to a better prognosis and decreased mortality in septic shock. Material and methods: descriptive statistics were used (measures of central tendency and dispersion, as well as frequencies and percentages). Likewise, inferential statistics were used with the Student's t test, χ2, ROC curve, area under the curve and Youden index, with a confidence interval of 95%. Results: the statistical association with mortality was presented in the clearance of standard base deficit and in lactate clearance. Conclusion: it was shown that lactate clearance and standard base deficit recorded at admission and at 24 hours were related to a better prognosis and decreased mortality in patients with septic shock.


Resumo: Introdução: a associação do nível de lactato com mortalidade em pacientes com suspeita de infecção e sepse está bem estabelecida. A sensibilidade está entre 66 e 83%, com especificidade de 80 e 85%. No entanto, o lactato não é sensível nem específico o suficiente para detectar ou descartar o diagnóstico por si só, uma vez que o lactato sérico é um importante biomarcador de hipóxia e disfunção tecidual, mas não é uma medida direta da perfusão tecidual. O lactato e a base padrão medidos na admissão na UTI são de utilidade prognóstica em pacientes críticos, uma vez que seus níveis séricos predizem a mortalidade pelo próprio escore. Mas a real importância vai além de um valor absoluto, pois é melhor medir sua depuração em um determinado tempo. Objetivo: demonstrar que a depuração de lactato e o déficit de base padrão registrados na admissão e em 24 horas estão relacionados a um melhor prognóstico e diminuição da mortalidade no choque séptico. Material e métodos: foi utilizada estatística descritiva (medidas de tendência central e dispersão, bem como frequências e percentagens). Da mesma forma, foi utilizada estatística inferencial com teste t de Student, χ2, curva ROC, área sob a curva e índice de Youden, com intervalo de confiança de 95%. Resultados: a associação estatística com a mortalidade foi apresentada na depuração do déficit de base padrão e na eliminação do lactato. Conclusão: foi demonstrado que a depuração de lactato e o déficit de base padrão registrados na admissão e em 24 horas foram relacionados a um melhor prognóstico e diminuição da mortalidade em pacientes com choque séptico.

SELECTION OF CITATIONS
SEARCH DETAIL